Search results for "Normal anatomy"
showing 3 items of 3 documents
Can the transverse foramen/vertebral artery ratio of double transverse foramen subjects be a risk for vertebrobasilar transient ischemic attacks?
2018
The C6 is the cervical vertebra into which the vertebral artery enters the passage of the transverse foramen and it is the vertebra most affected by double transverse foramina. There is currently little information about the relation between the vertebral artery and the double transverse foramen in C6. We aimed to test whether subjects with a double transverse foramen in C6 have a reduced transverse foramen/vertebral artery ratio when compared with normal anatomy subjects who possess a single transverse foramen which may be a risk for transient vertebral artery stenosis. We measured the area of the transverse foramen and the vertebral artery in 27 double transverse and 56 normal anatomy sub…
The anatomy of the proximal radius: implications on fracture implant design.
2012
Background The proximal radius features a complex anatomy. Several studies have been published on the anatomy using different technical approaches; however, most of these studies were conducted with a special focus on parameters relevant to radial prosthetic design. The purpose of our study was to explore the complex geometry of the proximal radius with regard to fracture implant design. Methods Our computed tomography-based measurements of 78 multiplanar reformatted radii allow for exact assessment of its geometry and offer a scientific rationale towards the design of fracture implants. We conducted measurements on the radial head, the radial neck, the radial tuberosity, the radial head-to…
3-D ultrasound in prenatal diagnosis
1999
Abstract 2-D ultrasonography has evolved into an excellent technique in prenatal diagnosis during the past 40 years. The fact remains, however, that 2-D ultrasonography is marked by a lack of ability to provide more than a 2-D demonstration of a 3-D fetus. Although many fetal anomalies are detectable by conventional 2-D ultrasound, it is impossible to demonstrate a defect in the third dimension. 3-D sonography not only offers the third plane, but it also provides the examiner with different viewing modes: the multiplanar, the surface and the transparent demonstration of the fetus. The different viewing modes not only improve the accuracy in detecting fetal malformations, but also serve to d…